Int Ophthalmol ; 43(11): 4131-4136, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37505289

RESUMO

INTRODUCTION: It is well known that the femtosecond laser lamellar cut induces some degree of surface roughness. Nevertheless, as in femtosecond laser-assisted LASIK (FS-LASIK), an excimer LASIK ablation is performed, and the post-ablation stromal bed should show some degree of smoothening. We decided to compare, using atomic force microscopy (AFM), the roughness of the corneal stromal bed, after a femtosecond lasers device flap was created with or without an excimer myopic ablation. METHODS: Using 6 freshly enucleated porcine eyes, we created in every eye a flap using a femtosecond laser. Additionally, in 3 eyes, an excimer laser ablation to correct-3 diopters (D) was made. AFM imaging of the remaining corneal stroma was performed. Ten different square areas of 20 µm x 20 µm at the central area of the stroma of each corneal sample were studied. The roughness parameters used were the root-mean-square deviation from a perfectly flat surface. RESULTS: The RMS deviation was 360 ± 120 nm in femtosecond laser only, and 110 ± 20 nm in those cases where excimer is also involved (p < 0.0001). CONCLUSIONS: Our results show that the roughness of the surface treated with excimer is clearly lower than in the group with no excimer ablation; thus, the application of laser excimer after a flap created by femtosecond laser seems to soften the nano-irregularities created by this technique.


Assuntos
Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Animais , Suínos , Microscopia de Força Atômica , Córnea/cirurgia , Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico
3.
Ophthalmol Ther ; 11(3): 1047-1066, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35262896

RESUMO

INTRODUCTION: To compare the influence of one microkeratome and three femtosecond lasers on myopic laser in situ keratomileusis (LASIK) outcomes. METHODS: Retrospective, observational cohort study. We compared 134 eyes treated with the IntraLase 60 kHz, 112 eyes treated with the Femto LDV Z6, 206 eyes treated with the FS200, and 98 eyes treated with the Hansatome zero compression microkeratome. All eyes were operated on using the same surgical protocol with the same excimer laser (Wavelight Allegretto) and were allocated to refraction-matched groups. RESULTS: One day and one week postoperatively, uncorrected distance visual acuity was significantly lower in the FS200 group compared to others (P = 0.0001). This difference disappeared at the 1- and 3-month postoperative visits. Significant differences were found among groups in terms of safety index (P = 0.0001), residual sphere (P = 0.0001), and residual cylinder (P = 0.02) at the 3-month postoperative visit. No significant differences were found in corrected distance visual acuity or efficacy index. CONCLUSION: According to our results, a slight delay in visual restoration after FS200 LASIK surgery might be expected. This delay was statistically significant at 1 day and 1 week postoperatively, but there were no differences from the 1-month visit onwards. Additionally, significant differences were found among devices in terms of safety index and the refractive results, which were found not to be clinically relevant.

4.
Eur J Ophthalmol ; 32(6): 3425-3432, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35254149

RESUMO

PURPOSE: To evaluate the visual and refractive outcomes of monofocal toric intraocular lens (IOL) implantation after cataract surgery in amblyopic eyes. METHODS: Our center's database was used to identify patients who had undergone bilateral cataract surgery between 2016 and 2020 with the implantation of a toric IOL in their amblyopic eye. Exclusion criteria were the presence of strabismus, ocular pathologies other than cataract or intra-surgical complications. The outcomes analysed were uncorrected distance visual acuity (UDVA), subjective refraction and corrected distance visual acuity (CDVA) one month after surgery. RESULTS: Ninety patients were included, with a mean age of 68.96 ± 7.81years. CDVA was lower for the amblyopic eye, both before and after surgery. There was a mean improvement in CDVA of 0.23 ± 0.21 LogMAR for the dominant eye and of 0.39 ± 0.33 for the amblyopic eye, p < 0.001 in both cases. Postoperative subjective refractive cylinder was higher in the amblyopic eye (-0.24 ± 0.39 D versus -0.10 ± 0.25 D, p < 0.01), as well as mean cylinder prediction error (-0.30 ± 0.47 D versus 0.02 ± 0.42 D, p < 0.01), compared to the dominant eye. There was a statistically significant correlation between preoperative and postoperative CDVA in amblyopic eyes (Spearmans Rho = 260, p = 0.013). Mean postoperative UCVA was 0.15 ± 0.25 for amblyopic and 0.03 ± 0.12 for dominant eyes. Only one patient required distance spectacle correction due to residual astigmatism. CONCLUSIONS: Cataract surgery with toric IOL implantation in amblyopic eyes leads to an improvement in visual acuity and to spectacle independence in almost all cases, even in the presence of a higher cylinder prediction error.


Assuntos
Ambliopia , Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Idoso , Ambliopia/complicações , Ambliopia/cirurgia , Astigmatismo/cirurgia , Catarata/complicações , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular
5.
Int Ophthalmol ; 42(1): 73-80, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34370173

RESUMO

INTRODUCTION: Higher preoperative myopic astigmatism is associated with a higher probability of retreatment due to patient dissatisfaction as a result of residual cylindrical error. Nonetheless, retreatment is safe and the final clinical results are comparable to those of patients with lower preoperative astigmatism who were satisfied with the primary treatment. Our purpose is to compare the efficacy and safety of femtosecond LASIK (FS-LASIK) for the refractive correction of patients with low (< 1.5 Diopters (D) versus high (≥ 1.5 D) myopic astigmatism. METHODS: Retrospective observational study of 841 eyes of 825 eligible patients treated with FSLASIK for the correction of simple or compound myopic astigmatism. Outcome measures included residual error, best corrected and uncorrected distance visual acuity (BCVA and UCVA), efficacy and safety 3 months after the primary procedure or the retreatment. RESULTS: Of 841 eyes in total, 432 (51.37%) had < 1.5 D (Group 1) and 409 (48.63%) had ≥ 1.5 D (Group 2) preoperative myopic astigmatism. The efficacy index of primary treatment was 0.94 ± 0.18 in Group 1 and 0.89 ± 0.22 in Group 2 (P = 0.001). Of 138 eyes (16.41%) that were retreated due to dis-satisfaction related to residual refractive error, 28 belonged to Group 1 (6.5%) and 110 (26.9%) to Group 2 (P < 0.001). Following retreatment, small but statistically significant differences in the residual mean postoperative cylinder (-0.08 ± 0.24 vs -0.27 ± 0.46 D, P = 0.001) and UCVA (1.11 vs 0.96, P = 0.0001) were detected for Groups 1 and 2, respectively. However, there were no statistically significant differences in the safety and efficacy indices. CONCLUSION: Following FS-LASIK, eyes with myopic astigmatism ≥ 1.5 D have approximately four times more chances of undergoing retreatment due to dis-satisfaction caused by residual refractive error compared to eyes with myopic astigmatism < 1.5 D. However, the clinical results after retreatment are highly satisfactory and comparable in both groups.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Astigmatismo/cirurgia , Substância Própria , Humanos , Lasers de Excimer/uso terapêutico , Miopia/complicações , Miopia/cirurgia , Refração Ocular , Resultado do Tratamento , Acuidade Visual
6.
BMC Ophthalmol ; 21(1): 280, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34261440

RESUMO

BACKGROUND: To compare the anterior surface roughness of two commercially available posterior chamber phakic intraocular lenses (IOLs) using atomic force microscopy (AFM). METHODS: Four phakic IOLs were used for this prospective, experimental study: two Visian ICL EVO+ V5 lenses and two iPCL 2.0 lenses. All of them were brand new, were not previously implanted in humans, were monofocal and had a dioptric power of - 12 diopters (D). The anterior surface roughness was assessed using a JPK NanoWizard II® atomic force microscope in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Anterior surface roughness measurements were made in 7 areas of 10 × 10 µm at 512 × 512 point resolution. The roughness was measured using the root-mean-square (RMS) value within the given regions. RESULTS: The mean of all anterior surface roughness measurements was 6.09 ± 1.33 nm (nm) in the Visian ICL EVO+ V5 and 3.49 ± 0.41 nm in the iPCL 2.0 (p = 0.001). CONCLUSION: In the current study, we found a statistically significant smoother anterior surface in the iPCL 2.0 phakic intraocular lenses compared with the VISIAN ICL EVO+ V5 lenses when studied with atomic force microscopy.


Assuntos
Cristalino , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular , Cristalino/cirurgia , Microscopia de Força Atômica , Estudos Prospectivos
7.
Transl Vis Sci Technol ; 10(3): 9, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34003943

RESUMO

Purpose: The purpose of this study was to measure the intraocular pressure (IOP) elevation during laser assisted in situ keratomileusis (LASIK) flap creation using the WaveLight FS200 femtosecond (FS) laser platform. Methods: We conducted an ex vivo experimental study in an animal model. The WaveLight FS200 FS laser platform was used to perform the corneal LASIK flap in freshly enucleated porcine eyes. We measured the changes in IOP from the application of the suction ring (suctioning phase) through the creation of the lamellar corneal flap (cutting phase). The IOP was recorded using a manometric technique with direct cannulation to the anterior chamber. Results: Nine freshly enucleated porcine eyes were included in the study. The mean baseline IOP before the procedure was 20.33 ± 5.9 mm Hg. The mean IOP increase over baseline IOP was 32.33 ± 11.3 mm Hg at the suctioning phase, and 38.22 ± 11.3 mm Hg at the cutting phase. The total surgical time needed to complete the procedure was 29.5 ± 4.4 seconds. Conclusions: The WaveLight FS200 FS laser platform produces a low to moderate increase in IOP during LASIK flap creation. Translational Relevance: The WaveLight FS200 is a safe FS laser platform because it induces a low to moderate IOP increase during LASIK flap creation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Animais , Pressão Intraocular , Lasers , Retalhos Cirúrgicos , Suínos , Tonometria Ocular
8.
PLoS One ; 16(5): e0252449, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34043738

RESUMO

PURPOSE: To compare the induced corneal stromal bed roughness measured with atomic force microscopy (AFM) after LASIK flap creation with the IntraLase 60 kHz and the VisuMax femtosecond laser platforms. METHODS: Three freshly enucleated porcine eyes were operated with each femtosecond laser in this experimental study. Standard LASIK treatment parameters were used for the experiment. After LASIK flap creation, the corneal stromal roughness was assessed using a JPK NanoWizard II® AFM in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Surface measurements were made in 10 regions of the central cornea of each sample measuring 20 x 20 microns, at 512 x 512 point resolution. Roughness was measured using the root-mean-square (RMS) value within the given regions. RESULTS: Measurements from 30 regions of the 3 eyes (10 measurements per eye) in the Intralase (FS1) group, and 30 regions of the 3 eyes (10 measurements per eye) in the VisuMax (FS2) group were analyzed. There was a statistically significant difference in mean ± standard deviation RMS values between the FS1 and the FS2 groups (360 ± 120 versus 230 ± 100 nm respectively; P< 0.00001). CONCLUSION: This AFM study indicates that the surface of the stromal bed after LASIK flap creation is smoother in the FS2 group than the FS1 group.


Assuntos
Substância Própria/fisiologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Microscopia de Força Atômica , Animais , Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Suínos , Fatores de Tempo
9.
Optom Vis Sci ; 98(4): 350-354, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33852551

RESUMO

SIGNIFICANCE: The development of confocal microscopy allows one to obtain high-resolution corneal images like its optical density. Some studies have evaluated the optical density with Scheimpflug cameras in the early post-operative period after photorefractive keratectomy, but no studies have evaluated the long-term evolution of optical density after surface ablation when mitomycin C is used. PURPOSE: This work aimed to study the changes in corneal optical density measured with confocal microscopy in eyes treated with laser-assisted subepithelial keratectomy (LASEK) and intraoperative mitomycin C (MMC) to correct myopia. METHODS: A study of 24 consecutive myopic eyes that underwent LASEK with 0.02% MMC and a control group of 24 healthy nontreated eyes was performed. Optical density was measured using the images by the confocal microscopy of the Heidelberg Retina Tomograph II with the Rostock Cornea Module. An analysis of confocal microscopy images was performed using the ImageJ software to obtain the optical density, in gray-scale units (GSU). The optical density of the stromal bed was evaluated 3 months, 15 months, and 3 years after surgery and was compared with the optical density at the equivalent depth of the stroma in controls. RESULTS: The mean values of optical density for the LASEK group were 81.7 ± 9.7, 78.6 ± 11.7, and 73.6 ± 18.7 GSU at 3 months, 15 months, and 3 years, respectively, and it was 61.8 ± 8.2 GSU for the control group. A statistically higher optical density 3 and 15 months after LASEK with MMC was found compared with controls (P < .001). No significant difference was found in optical density at 3 years post-operatively. CONCLUSIONS: Our study suggests that, after LASEK with MMC, the anterior corneal stroma has a higher optical density at 3 and 15 months post-operatively, which gradually returns to normal values 3 years after surgery.


Assuntos
Alquilantes/administração & dosagem , Córnea/fisiopatologia , Ceratectomia Subepitelial Assistida por Laser/métodos , Lasers de Excimer/uso terapêutico , Mitomicina/administração & dosagem , Miopia/cirurgia , Refração Ocular/fisiologia , Adulto , Biometria , Terapia Combinada , Córnea/diagnóstico por imagem , Córnea/efeitos dos fármacos , Substância Própria/diagnóstico por imagem , Substância Própria/efeitos dos fármacos , Substância Própria/fisiopatologia , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Miopia/diagnóstico por imagem , Miopia/fisiopatologia , Estudos Prospectivos , Adulto Jovem
10.
Int Ophthalmol ; 41(1): 163-172, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32844238

RESUMO

PURPOSE: To report visual outcomes and patient-perceived satisfaction after trifocal or extended depth-of-focus (EDOF) intraocular lens (IOL) implantation in a real-world scenario. METHODS: Three months after bilateral cataract surgery, corrected and uncorrected visual acuity for far, intermediate and near distances and binocular defocus curves and contrast sensitivity were measured. The patients also completed the Catquest SF-9 questionnaire and reported on dysphotopsia and spectacle use. RESULTS: There were 23 patients in the Symfony, 32 patients in the Finevision and 36 patients in the Panoptix group. The percentage of eyes receiving a toric IOL was 41.2%. There were no differences in uncorrected binocular visual acuities, save for near vision, which was lower in the Symfony group. Binocular defocus curves for the trifocal IOLS were almost identical, while vision achieved with the Symfony IOL was significantly lower starting at - 1.5 D defocus. Contrast sensitivity, as well as the perception of halos and glare and the difficulty for night-driving was similar for all groups, except for contrast sensitivity at 6 cycles per degree, which was lower in the Symfony group compared to both Finevision and Panoptix. For near vision, only 47.6% of the Symfony patients reported being completely spectacle-free, compared to 93.3% and 94.4% for the Finevision and Panoptix groups. CONCLUSIONS: Clinically relevant differences were only detected for near vision, with lower values for EDOF IOLs. In order to achieve patient satisfaction, it is imperative to explain the results expected with each IOL; for EDOF IOLs, patients should be advised that they may require near-spectacle correction.


Assuntos
Óculos , Lentes Intraoculares , Humanos , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Pseudofacia , Refração Ocular , Visão Binocular
11.
Clin Exp Optom ; 104(1): 14-21, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32342559

RESUMO

CLINICAL RELEVANCE: The control of myopia progression is currently considered an evidence-based therapeutic need. BACKGROUND: To determine the efficacy and safety of the Esencia lens, a new soft contact lens (SCL) designed to slow down myopia progression in paediatric patients. METHODS: This study was a randomised, parallel, double-masked clinical trial. Seventy myopic (-0.50 to -8.75 D) boys and girls, 7-15-years of age, were randomised and allocated to one of two groups: (i) study (n = 36) or (ii) control (n = 34). Study group patients were given the Esencia lens, a progressive multifocal and reverse geometry SCL. Control group patients were given conventional SCLs. Efficacy measurements (change in cycloplegic autorefraction and axial length) were measured at baseline and at the six-month intervals over a 12- month period. Visual performance measurements were corneal power, comfort, quality of vision and contact lens fitting. Safety measures included detection of adverse events. RESULTS: Mean changes in cycloplegic autorefraction after 12-months were -0.28 ± 0.35 D for study and -0.57 ± 0.52 D for control group patients (p = 0.02). A significantly lower increase in axial length was found in the study group (0.13 ± 0.12-mm) compared to control (0.22 ± 0.14-mm) patients (p = 0.03). Compared to control group patients, there was less myopia progression in the study group: 51 and 41 per cent in terms of cycloplegic autorefraction and axial length, respectively. No significant differences between groups for change in corneal power, comfort, vision quality and contact lens fitting were found (p > 0.05). Regarding safety, there were no serious and/or unexpected adverse events during the study. CONCLUSIONS: The Esencia lens seems to be efficacious in slowing down progression of myopia in children compared to traditional SCLs in the short term, with comparable safety features and visual outcomes.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Adolescente , Criança , Lentes de Contato Hidrofílicas/efeitos adversos , Córnea , Progressão da Doença , Feminino , Humanos , Masculino , Miopia/terapia , Refração Ocular
12.
Eye Contact Lens ; 47(4): 213-218, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33323876

RESUMO

OBJECTIVE: The objective of this study was to assess the impact of 0.50 diopter (D) positive or negative defocus on visual function in patients implanted with trifocal and trifocal toric intraocular lenses (IOLs). METHODS: The study included patients implanted with the AcrySof IQ PanOptix IOL or the PanOptix Toric. Visual acuity (VA) at high (100%), medium (50%) and low (10%) contrast, contrast sensitivity function (CSF), and halo perception were assessed three months after surgery. Explorations were performed with corrected distance visual acuity (CDVA), with a positive defocus of +0.50D (myopization) and with a negative defocus of -0.50D (hyperopization). RESULTS: The study included 60 eyes of 60 patients (30 eyes with PanOptix and 30 eyes with PanOptix Toric). For both groups, VA was better for all contrast settings at the CDVA situation (P<0.05 in all cases). For low spatial frequencies, no differences in CSF were found among the three refractive situations in either group. For higher frequencies, the results showed an overall trend for better CSF results for the CDVA situation. The halo effect was lower for the CDVA situation if compared to myopization and hyperopization in both the PanOptix and the PanOptix Toric groups (P<0.05 for all cases). CONCLUSIONS: There is an impact on visual quality and halo perception in patients implanted with trifocal or trifocal toric IOLs even for low residual refractive errors.


Assuntos
Lentes Intraoculares , Facoemulsificação , Erros de Refração , Humanos , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Refração Ocular , Erros de Refração/terapia
13.
J Cataract Refract Surg ; 46(9): 1278-1283, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32898096

RESUMO

PURPOSE: To assess the relevance of the homogeneity of femtosecond laser flap thickness regarding induction of higher-order aberrations (HOAs). SETTING: Clínica Rementería & Clínica Novovisión, Madrid, Spain. DESIGN: Prospective observational study. METHODS: Two hundred thirty-one patients underwent in situ keratomileusis using 5 different femtosecond lasers. The flap thicknesses were measured using anterior segment optical coherence tomography 3 months postoperatively. The same masked observer measured 6 symmetrical points nasally and temporally 1.0 mm, 2.0 mm, and 3.0 mm from the center of the flap in each case. HOAs induced in the cornea were measured using tomography. RESULTS: Positive and significant correlations were found between HOA induction and the flap thickness heterogeneity 3.0 mm from the center of the flap. Pearson correlation coefficients for the induction of HOAs were third-order 0.17112 (P = .0224), fourth-order 0.22474 (P = .0026), fifth-order 0.16449 (P = .0282), coma-like 0.17370 (P = .0204), and total HOAs 0.18182 (P = .0151). CONCLUSIONS: The amount of flap-thickness heterogeneity at 3.0 mm from the center of the flap created using femtosecond lasers was correlated with the magnitude of the HOAs induced.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Substância Própria/diagnóstico por imagem , Substância Própria/cirurgia , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Espanha , Acuidade Visual
14.
J Ophthalmol ; 2020: 2421816, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32377414

RESUMO

METHODS: Our center's database was used to identify all isolated cataract procedures performed during 2017. The electronic records were reviewed to collect the preoperative information, presence of intra- or postsurgical complications, and visual and refractive outcomes one month after surgery. RESULTS: In 2017, 2714 eyes of 1543 patients underwent cataract surgery in our center. Mean patient age was 70.42 years. 775 eyes (28.55%) had prior ophthalmic pathologies, and 113 eyes (4.16%) had undergone previous surgical procedures. Surgical complications developed in 35 eyes (1.29%), including 9 posterior capsule tears (0.33%) and 3 cases of dropped lens fragments (0.11%). A toric or multifocal intraocular lens was implanted in 45.6% of eyes. As regards postoperative complications, 59 eyes (2.17%) required a return to the operating theater, including 29 eyes (1.07%) requiring reinterventions due to an unexpected refractive result. There were no cases of endophthalmitis. Mean LogMAR-corrected distance visual acuity (CDVA) improved from 0.25 (SD 0.34) preoperatively to 0.04 (SD 0.17) postoperatively; 86.5% of eyes achieved a CDVA ≤0.0, with 97.5% achieving ≤0.3. In 86.4% of eyes, the difference between target and residual spherical equivalent difference was of 0.50 D or lower; 88% of eyes had a spherical equivalent ±0.50 D. CONCLUSIONS: The visual and refractive outcomes of cataract surgery in a private practice setting were excellent, well over the benchmarks set by the ESCRS. The safety profile was also within expected standards. This study provides information for ophthalmologists in private practice on expected outcomes.

16.
J Cataract Refract Surg ; 46(2): 260-266, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32126040

RESUMO

PURPOSE: To describe the postoperative evolution of visual acuity, flap morphology, and stromal optical density femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). SETTING: Clínica Rementería, Madrid, Spain. DESIGN: Prospective case series. METHODS: The study comprised 44 consecutive eyes that had FS-LASIK performed with the WaveLight FS200 and the Allegretto excimer laser to correct myopia. Visual outcomes, flap thickness, and stromal optical density were assessed 1 day, 1 week, 1 month, and 3 months postoperatively. RESULTS: A statistically significant improvement in the mean uncorrected distance visual acuity at 1 day (0.94 ± 0.2) and 1 week (0.93 ± 0.2) to 1 month (1.04 ± 0.2) and 3 months (1.11 ± 0.1) postoperatively (P < .05). At 3 months postoperatively, the femtosecond laser had good outcomes in efficacy (0.98 ± 0.1), safety (0.98 ± 0.1), and predictability (100% of eyes were within ± 0.5 D of emmetropia). The femtosecond-created flaps were slightly thicker than intended, the mean SD intraflap was 7.1 µm, the range between the thickest and thinnest points in each flap was 25.4 µm, and the mean flap thickness homogeneity was 7.6 µm at 3 months postoperatively. A progressive decrease in the optical density of the flap stroma and the residual stromal bed was detected during follow-up. CONCLUSIONS: The femtosecond laser study appears to be a safe, effective, and predictable platform to obtain LASIK flaps. The flaps were planar and homogeneous but slightly thicker than intended. The optical density of the flap stroma was slightly higher at early follow-up and decreased over time.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Retalhos Cirúrgicos/patologia , Acuidade Visual/fisiologia , Adulto , Paquimetria Corneana , Substância Própria/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Tamanho do Órgão , Estudos Prospectivos , Refração Ocular/fisiologia , Tomografia de Coerência Óptica , Resultado do Tratamento , Adulto Jovem
18.
BMC Ophthalmol ; 19(1): 205, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31615462

RESUMO

BACKGROUND: To compare the visual and refractive outcomes after myopic LASEK using three different excimer lasers and standardized surgical and mitomycin C (MMC) application protocols. METHODS: In this retrospective, observational cohort study, we examined 122 eyes treated with Allegretto, 135 eyes treated with Esiris and 137 eyes treated with Technolas excimer lasers. All eyes were treated under the same surgical protocol, and a standardized MMC dosage was used. The three groups were refraction-matched, and both visual and refractive outcomes were evaluated at 1 and 7 days and 1 and 3 months after surgery. RESULTS: At 3 months postsurgery, Allegretto provided significantly better outcomes than Esiris and Technolas in terms of postoperative uncorrected distance visual acuity (UDVA) (1.11 ± 0.2 vs 1.01 ± 0.2 vs 0.98 ± 0.2) (P = 0.0001), corrected distance visual acuity (CDVA) (1.13 ± 0.2 vs 1.10 ± 0.1 vs 1.04 ± 0.2) (P = 0.0001), residual sphere (- 0.01 ± 0.2 vs + 0.29 ± 0.7 vs + 0.27 ± 0.6) (P = 0.0001), and efficacy index (0.99 ± 0.2 vs 0.90 ± 0.2 vs 0.91 ± 0.2) (P = 0.0004). CONCLUSIONS: We found slightly better visual and refractive outcomes in the Allegretto group at 3 months post-op after LASEK with MMC to correct myopia.


Assuntos
Ceratectomia Subepitelial Assistida por Laser/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Feminino , Seguimentos , Humanos , Masculino , Miopia/fisiopatologia , Período Pós-Operatório , Estudos Retrospectivos , Fatores de Tempo
19.
Graefes Arch Clin Exp Ophthalmol ; 257(12): 2665-2670, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31650272

RESUMO

PURPOSE: To describe and compare the stromal bed roughness obtained after laser in situ keratomileusis (LASIK) flap creation using a corneal femtosecond laser platform (iFS 150) and a "dual" femtosecond (FS) laser platform (LenSx). METHODS: This ex vivo experimental study was conducted in an animal model using 12 freshly enucleated porcine eyes, six with each femtosecond laser. The standard laser treatment parameters were used for the experiment. After LASIK flap creation, the corneal stromal roughness was assessed using atomic force microscopy (AFM) in contact mode immersed in liquid. In each sample, surface measurements were obtained in 60 regions of six eyes per FS laser in 10 20 × 20-micron areas of the central corneal stroma at 512 × 512-point resolution. The surface roughness was measured and the root-mean-square (RMS) values of the roughness were obtained. RESULTS: The mean RMS ± standard deviation values were 430 ± 150 nm for the corneal femtosecond laser platform and 370 ± 100 nm for the dual FS laser platform (P < 0.011). CONCLUSIONS: In this experimental study with AFM, we found smoother stromal beds after LASIK flap creation with LenSx compared to iFS 150 kHz. Further studies are needed to understand visual implications of the differences found.


Assuntos
Substância Própria/patologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Retalhos Cirúrgicos , Acuidade Visual , Animais , Substância Própria/cirurgia , Modelos Animais de Doenças , Microscopia de Força Atômica , Miopia/patologia , Período Pós-Operatório , Suínos
20.
J Cataract Refract Surg ; 45(10): 1490-1497, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31399323

RESUMO

PURPOSE: To perform in vitro assessments of surface haze and roughness, subsurface nanoglistenings (SSNGs), and glistenings of a new hydrophobic acrylic intraocular lens (IOL) in comparison to commercially available IOLs. SETTING: Universities of Utah and Alcalá, and Alcon Vision, LLC. DESIGN: Experimental study. METHODS: The IOLs used were Clareon CNA0T0, Tecnis ZCB00 and Tecnis OptiBlue ZCB00V, Eternity W-60, enVista MX60, and Vivinex XY1. Surface haze was assessed by the pixel intensity units (PIU) from cross-sectional slitlamp images, and it was correlated to atomic force microscopy roughness. For SSNGs, the IOLs were artificially aged up to 10 years, followed by Scheimpflug densitometry (computer-compatible tape unit [CCTU]) measurements. For glistenings, the IOLs were immersed in a water bath and subjected to temperature changes before analysis. RESULTS: The surface haze (n = 10, PIU) was 4.25 ± 0.87 (SD) (CNA0T0), 9.50 ± 1.66 (ZCB00), 39.48 ± 1.97 (ZCB00V), 46.68 ± 3.16 (W-60), 44.70 ± 4.00 (MX60), and 4.42 ± 0.71 (XY1) (P < .001), which showed a strong correlation with surface roughness measurements (R = 0.94, P = .006). The densitometry (n = 10, CCTU at 10 years) was 7.30 ± 1.36 (CNA0T0), 11.88 ± 3.10 (ZCB00), 38.12 ± 2.24 (ZCB00V), 48.13 ± 9.44 (W-60), 20.20 ± 3.84 (MX60), and 6.75 ± 6.66 (XY1) (P < .001), with no significant differences between CNA0T0 vs. ZCB00 and XY1. The glistenings density (n = 30) was the lowest for the CNA0T0, W-60, and MX60 IOLs. CONCLUSIONS: The new Clareon CNA0T0, which is manufactured from a hydrophobic acrylic material, exhibited among the lowest levels of surface haze and roughness, SSNGs, and glistenings compared with other commercially available hydrophobic acrylic IOLs.


Assuntos
Resinas Acrílicas , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Elastômeros de Silicone , Estudos Transversais , Humanos , Interações Hidrofóbicas e Hidrofílicas , Polimetil Metacrilato , Estudos Prospectivos